R&S®XU250A/XD230A VHF/UHF Multichannel Transceiver
Options
| Designation Type | Uses, specifications, features and benefits |
|---|---|
| Auxiliary Equipment | |
| Standard Racks R&S® KG2000 | Optimized for ATC systems with R&S® Series200 communication equipment Note: For further information, see Related Links at the bottom of this page |
| AF Remote Control Unit R&S® GB208 | Control of up to eight radio channels from a single operator position Note: For further information, see Related Links at the bottom of this page |
| Control Panel R&S® GB409 | Remote operation of a standalone transceiver Typical application: airline-internal company radio Functions: the R&S® GB409 offers a minimum offunctions (no main/standby or manual/auto etc) for R&S®Series200; for more sophisticated control and monitoring conceptsrefer to REM BUS or INBAND techniques Design: ¼ 19"plug-in (3 HU) for desk integration (directly or via 19" AdapterR&S® KR405, depending on desk design) Dimensions (W × H × D): 100 mm × 132 mm × 175 mm |
| .02 | Functions: AF, S/N SQL, PTT, carrier, test,on/off Distance: <50 m with 28 V DC from transceiver orsome 100 m with local DC supply (22 V to 30 V DC) Cabling: 6DC permeable + 4 AF lines; shielded cable |
| .03 | Functions: AF, AF SQL, PTT (2040 Hz INBAND tone via TXAF) Power supply: local AC or DC (alternativelywired) Distance: nearly unlimited Cabling: 2-pair AFchannel (telephone or MW path) Additional radio requirement:R&S® GM211 (.20) and R&S® GM211-S (.25) |
| .04 | Functions: AF, AF SQL, PTT (2040 Hz INBAND tone via TX AF, 100%INBAND control and monitoring/test (in connection with R&S®GM231A only) Power supply: local AC or DC supply (R&S®GB409 alternatively wired) Distance: nearlyunlimited Cabling: a) Radio to R&S® GM231A: 2-pair AFchannel (telephone or MW path) b) R&S® GM231A to GB409: 6wires Additional radio requirement R&S® GM211 (.20) andR&S® GM211-S (.22) |
| Control Unit R&S® GB406C1 | Remote operation of multichannel radios
|
| Control Software R&S® GB406-S | Application-specific and factory-loaded software (EPROM forR&S® GB406C1) Note: The R&S® GB406-S has to be ordered separately together with the control units (equal quantities) |
| Cabinet R&S® KK406 | For variable desktop installation of R&S® GB406C1 Dueto its swivel-type mounting holder the R&S® KK406 offers afine-graded adaptability for optimum sight and operator convenience |
| 19" Adapter R&S® KR405 | Desk integration of up to 4 Control Panels R&S® GB409, 19" 3HU |
| AC Power Supply R&S® NGRA24 | AC Power Supply for rack integration 24 V/1.25 A; profile rackmounting |
| AF distribution splitter/combiner R&S® GH215 | Active AF line combiner and AF line splitter for rackintegration |
| Option for R&S® GH215 R&S® KR215 | 19" mounting frame for 8 × R&S® GH215x |
| AF distribution passive splitter/combiner R&S® GH215P | With separate output for voice recorder |
| Service Kit RX R&S® KA231 | Maintenance and testing, troubleshooting andrepair Special-to-type test kit for
The kitincludes all necessary test adapters, cables and REM BUS testsoftware, all packed in a handy portable case with individuallyshaped foam inserts and user information |
| Service kit TX R&S® KA251 |
For further details see R&S® KA231 |
| Accessories | |
| Cable R&S® KS201C | For a RX main/standby pair (RXA + RXB): for horizontal connection of 2 receivers installed in neighbouring slots of one R&S® KR231A8 19" adapter |
| Cable R&S® KS201C | For a RX main/standby pair (RXA + RXB): for vertical connection of 2 receivers installed in the same slot of two stacked R&S® KR231A8 19" adapters |
| Cable R&S® KS201C | For RX REM Bus and DC supply of R&S® VT231 (+ R&S® GT231T1), for connection of
Thus 2 cables are required for a completely equipped R&S® KR231A8 19" adapter. This special flat-type bus cable has mating connectors to link two cables |
| Set of mating connectors R&S® KS201 | For R&S® IN201A power supply which is part of the R&S® EU/ED231A receivers or R&S® GM231A INBAND control Note: The RF (BNC) plug type for the receive antenna cable depends on the feeder type and is therefore not included in the set. See comment on R&S® KS231. |
| Set of mating connectors R&S® KS231 | For R&S® VT231 VHF/UHF multicoupler IBIT (X11) and REM Bus (X15) connectors. The R&S® VT231 itself includes 7 fixed connected RF cables with mounted BNC plugs and graded lengths matching the associated receivers RX1 to RX7 Note 1: R&S® KS231 does not include RF connectors for antenna and cascading output (connector types depend on cable type) Note 2: For RX REM Bus connection X10 (including DC supply of R&S® VT231) with associated receivers the R&S® KS201C special cable model .04 is available |
1) In contrary to options, which can be additionally integrated into basic modules or equipment, auxiliary equipment for R&S® Series200 is defined to be standalone equipment for operation or service. The following types are important system components for complete VHF/UHF radio systems or for qualified maintenance, testing, troubleshooting and repair.